{"title":"DSE Deep Sea Electronics","description":"\u003cp\u003eDSE or Deep Sea Electronics is one of the world’s top manufacturers of generator control systems, auto transfer switches and battery charger equipment. Contact Macfarlane Generators today to discuss your requirements\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003cp\u003eNote: Freight excluded unless otherwise stated\u003c\/p\u003e","products":[{"product_id":"12v-dsebc1205-deep-sea-electronics-battery-charger","title":"12V DSEBC1205 Deep Sea Electronics Battery Charger","description":"\u003cp class=\"description\"\u003eThe DSEBC1205 is designed to be permanently connected to a battery, to ensure it maintains a full charge. The charger includes LED indicators on the front that show when there is no battery connected and if a fault condition is present. \u003cbr\u003e\n\u003cbr\u003e\nThe chargers continue to operate during cranking \u0026amp; running and have been designed to accept multiple AC voltage connections. The robust design makes the charger ideally suited to a wide range of markets including heavy and light industrial environments.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eMulti-Stage Intelligent Charging:Constant current- Maximum current available during charge recovery phaseConstant voltageChargers automatically return to float mode when charging is completeLow Output Ripple:Makes the chargers ideal for all battery typesFull Protection:Reverse polarity protection, short circuit protection and current limitingAutomatic recovery after the removal of fault conditionsBoost Mode:Boosts and equalises cell charge improving battery performance and lifeSimple boost connection using on-board terminalsPower Save Mode:Once the battery is fully charged the chargers switch to Eco-Power to save energy | Small and CompactNo moving parts for longer battery charger lifeSwitched mode designCharge fail outputMinimum 80% efficiency throughout full operating rangeParalleling Feature:Multiple modules can be linked together to provide larger current output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAC Supply:\u003c\/th\u003e\n\u003ctd\u003eVoltage Range: 90 V to 305 V (L-N) DC Output: 5 A DC 12 V DC Ripple and Noise: \u0026lt;3% Vo Efficiency: \u0026gt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRegulation:\u003c\/th\u003e\n\u003ctd\u003eLine: \u0026lt;1% Load: \u0026lt; 4% Vo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProtections:\u003c\/th\u003e\n\u003ctd\u003eShort Circuit Reverse Polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions:\u003c\/th\u003e\n\u003ctd\u003eOverall: 129.6 mm x 138.5 mm x 50 mm, 5.1” x 5.45” x 2.0” Weight: 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52592034709780,"sku":"2520","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/12V-DSEBC1205-Deep-Sea-Electronics-Battery-Charger_69f9be54-3be4-4686-a764-958d7798c0f6.jpg?v=1780693998"},{"product_id":"24v-dse9255-deep-sea-electronics-battery-charger","title":"24V DSE9255 Deep Sea Electronics Battery Charger","description":"\u003cp class=\"description\"\u003eDeep Sea Electronics 24V 5 Amp DSE9255 Battery Charger has been designed to be permanently connected to a battery, keeping it charged to maximum capacity. The chargers can be either mounted via DIN rail or to the chassis, using the fixing holes that are built into the case. The chargers stylish design includes an LED indicator on the front that shows when the charger is in a normal or overload condition. Special Price is valid for a limited time only!\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eMulti-Stage Intelligent Charging:• Constant current- Maximum current available during charge recovery phase• Constant voltage• Chargers automatically return to float mode when charging is completeLow Output Ripple:• Makes the chargers ideal for all battery typesFull Protection:• Reverse polarity protection, short circuit protection and current limiting• Automatic recovery after the removal of fault conditionsBoost Mode:• Boosts and equalises cell charge improving battery performance and life• Simple boost connection using on-board terminalsPower Save Mode:• Once the battery is fully charged the chargers switch to Eco-Power to save energy | • Suitable for a wide range of battery types• No moving parts for longer battery charger life• Switched mode design• Charge fail output• Minimum 80% efficiency throughout full operating rangeParalleling Feature:• Multiple modules can be linked together to provide larger current output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAC Supply:\u003c\/th\u003e\n\u003ctd\u003eVoltage Range: 90 V to 305 V (L-N) DC Output: 5 A DC 24 V DC at 27.4 V DC Ripple and Noise: \u0026lt;1% Efficiency: \u0026gt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eRegulation:\u003c\/th\u003e\n\u003ctd\u003eLine: \u0026lt;0.001% Vo Load: 1% Vo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eProtections:\u003c\/th\u003e\n\u003ctd\u003eShort Circuit Over Voltage Over Current Reverse Polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDimensions:\u003c\/th\u003e\n\u003ctd\u003eOverall: 136 mm x 140 mm x 63 mm, 5.4” x 5.5” x 2.5” Weight: 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52593446748436,"sku":"826","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/24V-DSE9255-Deep-Sea-Electronics-Battery-Charger_b83e5e22-162c-4084-beb4-5b57b56e412c.jpg?v=1780696868"},{"product_id":"dse7310mkii-auto-start-control-module","title":"DSE7310MKII Auto Start Control Module","description":"\u003cp class=\"description\"\u003eThe DSE7310 MKII is a powerful, new generation auto start genset control module with a highly sophisticated level of new features and functions, presented in the usual DSE user-friendly format. Suitable for a wide variety of single, diesel or gas Gen-set applications. \u003cbr\u003e\n\u003cbr\u003e\nThe DSE7310MKII Featurs a new Dual Core main processor and extended memory, the module provides faster and more powerful processing power, returning faster operational responses on intensive applications and increased functionality, with data logging facility. \u003cbr\u003e\n\u003cbr\u003e\nMonitoring an extensive number of engine parameters, the module will display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LED's, remote PC's and via SMS text alerts (with external communication device).\u003cbr\u003e\n\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eDC SUPPLY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContinuous Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e8 V to 35 V Continuous 5 V for up to 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCranking Dropouts\u003c\/th\u003e\n\u003ctd\u003eAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Operating Current\u003c\/th\u003e\n\u003ctd\u003e510 mA at 12 V, 240 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Standby Current\u003c\/th\u003e\n\u003ctd\u003e330 mA at 12 V, 160 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCharge Fail\/Excitation Range\u003c\/th\u003e\n\u003ctd\u003e0 V to 35 V | OUTPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput A (Fuel)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput B (Start)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutputs C \u0026amp; D\u003c\/th\u003e\n\u003ctd\u003e8 A 250 V (Volt free)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary Outputs E, F, G \u0026amp; H\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage | GENERATOR \u0026amp; MAINS UTILITY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.5 V to 70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e10,000 Hz (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52597133279508,"sku":"1136","price":1800.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/DSE7310MKII-Auto-Start-Control-Module_cbaf2de2-8194-4c3a-83d5-af1e80707abd.jpg?v=1780704276"},{"product_id":"dse4520-mkii-auto-mains-failure-control-module","title":"DSE4520 MKII Auto Mains Failure Control Module","description":"\u003cp class=\"description\"\u003eThe DSE4520 MKII is a compact Auto Mains (Utility) Failure Control Module that has been developed to provide an outstanding range of features within a compact enclosure. \u003cbr\u003e\n\u003cbr\u003e\nTHE MODULE CAN BE CONFIGURED FOR USE AS AN AUTO START CONTROL MODULE. \u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eDC SUPPLY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContinuous Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e8V to 35V Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCranking Dropouts\u003c\/th\u003e\n\u003ctd\u003eAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Operating Current\u003c\/th\u003e\n\u003ctd\u003e85mA at 12V, 96mA at 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Standby Current\u003c\/th\u003e\n\u003ctd\u003e51 mA at 12 V, 47 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Sleep Current\u003c\/th\u003e\n\u003ctd\u003e35 mA at 12 V, 32 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Deep Sleep Current\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;10 uA at 12 V, \u0026lt;10 uA at 24 V | OUTPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutputs A (Fuel)\u003c\/th\u003e\n\u003ctd\u003e10 A short term, 5 A continuous, at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutputs B (Start)\u003c\/th\u003e\n\u003ctd\u003e10 A short term, 5 A continuous, at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary Outputs C \u0026amp; D\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage ­­ | GENERATORS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e15 V to 415 V AC (Ph to N), 26 V to 719 V AC (Ph to Ph)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e3.5 Hz to 75 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52597158674708,"sku":"2372","price":1089.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/DSE4520-MKII-Auto-Mains-Failure-Control-Module_65740b82-83c7-4952-9b2e-f0ba4c2df75b.jpg?v=1780704294"},{"product_id":"dse7410-mkii-auto-start-control-module","title":"DSE7410 MKII Auto Start Control Module","description":"\u003cp class=\"description\"\u003eThe DSE7410 is a sophisticated mono display auto start control module packed with industry leading features to enhance single-set control. The module can be used across a wide range of diesel and gas gen-set applications.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eDC SUPPLY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContinuous Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e8 V to 35 V Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCranking Dropouts\u003c\/th\u003e\n\u003ctd\u003eAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Operating Current\u003c\/th\u003e\n\u003ctd\u003e260 mA at 12 V, 130 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Standby Current\u003c\/th\u003e\n\u003ctd\u003e120 mA at 12 V, 65 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCharge Fail\/Excitation Range\u003c\/th\u003e\n\u003ctd\u003e0 V to 35 V | OUTPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput A (Fuel)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput B (Start)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutputs C \u0026amp; D\u003c\/th\u003e\n\u003ctd\u003e8 A AC at 250 V AC (Volt free)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary Outputs E, F, G, H, I \u0026amp; J\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage | GENERATOR\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.5 V to 70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e10,000 Hz (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52597170962708,"sku":"1137","price":1776.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/DSE7410-MKII-Auto-Start-Control-Module_13ea5776-ca4f-45eb-a171-933c0fde2321.jpg?v=1780704310"},{"product_id":"dse8620-mkii-load-sharing-synchronising-control-module","title":"DSE8620 MKII Load Sharing \u0026 Synchronising Control Module","description":"\u003cp class=\"description\"\u003eSynchronising \u0026amp; Load Sharing Auto Mains (Utility) Failure Control Module.\u003cbr\u003e\n\u003cbr\u003e\nThe DSE8620 is an intelligent mono display auto mains (utility) failure load share control module packed with industry leading features to enhance paralleling single gensets with a mains (utility) supply. \u003cbr\u003e\n\u003cbr\u003e\nThe DSE 8620 automatically controls the change over between mains (utility) and generator power and can also be configured to run a generator in synchronisation with a mains (utility) supply. \u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eDC SUPPLY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContinuous Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e8 V to 35 V Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCranking Dropouts\u003c\/th\u003e\n\u003ctd\u003eAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Operating Current\u003c\/th\u003e\n\u003ctd\u003e460 mA at 12 V, 245 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Standby Current\u003c\/th\u003e\n\u003ctd\u003e375 mA at 12 V, 200 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCharge Fail\/Excitation Range\u003c\/th\u003e\n\u003ctd\u003e0 V to 35 V | OUTPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput A (Fuel)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput B (Start)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutputs C \u0026amp; D\u003c\/th\u003e\n\u003ctd\u003e8 A 250 V (Volt free)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary Outputs E, F, G, H, I \u0026amp; J\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage | GENERATOR \u0026amp; MAINS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.5 V to 70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e10,000 Hz (max) | BUILT IN GOVERNOR AND AVR CONTROL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMinimum Load Impedance\u003c\/th\u003e\n\u003ctd\u003e1000Ω Fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eGain Voltage\u003c\/th\u003e\n\u003ctd\u003e0 V to 10 V DC Fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOffset Voltage\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 V DC Fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52597178499348,"sku":"1139","price":3845.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/DSE8620-MKII-Load-Sharing-Synchronising-Control-Module_f5f6c63f-5d60-4567-849c-bf09cefc0349.jpg?v=1780704333"},{"product_id":"dse8660mkii-load-sharing-synchronising-control-module","title":"DSE8660MKII Load Sharing \u0026 Synchronising Control Module","description":"\u003cp class=\"description\"\u003eThe DSE8660 MKII is the latest and most advanced Auto Transfer Switch \u0026amp; Mains (Utility) Control Module within the DSE synchronising and load sharing control module range. Developed alongside the DSE8610 MKII this control module provides industry-leading features and benefits for the most complex grid type generator installations. \u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eDC SUPPLY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContinuous Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e8 V to 35 V Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCranking Dropouts\u003c\/th\u003e\n\u003ctd\u003eAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Operating Current\u003c\/th\u003e\n\u003ctd\u003e460 mA at 12 V, 245 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Standby Current\u003c\/th\u003e\n\u003ctd\u003e375 mA at 12 V, 200 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCharge Fail\/Excitation Range\u003c\/th\u003e\n\u003ctd\u003e0 V to 35 V | OUTPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput A (Fuel)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput B (Start)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutputs C \u0026amp; D\u003c\/th\u003e\n\u003ctd\u003e8 A AC at 250 V AC (Volt free)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary Outputs E, F, G, H, I \u0026amp; J\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage | GENERATOR \u0026amp; BUS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.5 V to 70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e10,000 Hz (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMinimum Load Impedance\u003c\/th\u003e\n\u003ctd\u003e1000Ω Fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eGain Voltage\u003c\/th\u003e\n\u003ctd\u003e0 V to 10 V DC Fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOffset Voltage\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 V DC Fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52597197898004,"sku":"1140","price":2607.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/DSE8660MKII-Load-Sharing-Synchronising-Control-Module_5a3668ef-6f48-4f4c-b2b9-f679f8fd7ba2.jpg?v=1780704349"},{"product_id":"dse3110-manual-and-autostart-module","title":"DSE3110 Manual and Autostart Module","description":"\u003cp class=\"description\"\u003eThe DSE3110 is an outstanding compact control module that provides a comprehensive range of features for single-set applications. The controller can be used in manual or auto start mode.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eDC SUPPLY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContinuous Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e8V to 35V Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCranking Dropouts\u003c\/th\u003e\n\u003ctd\u003eAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCharge Fail\/ Excitation\u003c\/th\u003e\n\u003ctd\u003e8V to 35V fixed power source 2.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eNominal Standby Current\u003c\/th\u003e\n\u003ctd\u003e23mA at 12 V, 18mA at 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Operating Current\u003c\/th\u003e\n\u003ctd\u003e35mA at 12V, 30mA at 24V | OUTPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput A (Fuel)\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput B (Start)\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary Outputs C \u0026amp; D\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage | GENERATOR\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.5 V to 70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e10,000 Hz (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52597210120468,"sku":"1130","price":294.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/DSE3110-Deep-Sea-Manual-Autostart-Module_0ef8e3e0-eb84-4491-aa9a-f9741d9f5952.jpg?v=1780704365"},{"product_id":"dse6110mkiii-auto-start-control-module","title":"DSE6110MKIII Auto Start Control Module","description":"\u003cp class=\"description\"\u003eThe DSE 6110 MKIII is an Auto Start Control Module developed to provide a wide range of operating and monitoring features for single diesel and gas gen-sets.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003ctd\u003eDC SUPPLY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eContinuous Voltage Rating\u003c\/th\u003e\n\u003ctd\u003e8V to 35V Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCranking Dropouts\u003c\/th\u003e\n\u003ctd\u003eAble to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 10 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Operating Current\u003c\/th\u003e\n\u003ctd\u003e260 mA at 12 V, 150 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eMaximum Standby Current\u003c\/th\u003e\n\u003ctd\u003e145 mA at 12 V, 85 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eCharge Fail\/Excitation Range\u003c\/th\u003e\n\u003ctd\u003e0 V to 35 V | GENERATOR \u0026amp; MAINS (UTILITY)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e15 V to 415 V AC (Ph to N) 26 V to 719 V AC (Ph to Ph)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003ctd\u003e3.5 Hz to 75 Hz | INPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eDigital Inputs A to H\u003c\/th\u003e\n\u003ctd\u003eNegative switching\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalogue Inputs A \u0026amp; D\u003c\/th\u003e\n\u003ctd\u003eConfigurable as: Negative switching digital input 0 V to 10 V sensor 4 mA to 20 mA sensor Resistive sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAnalogue Inputs B \u0026amp; C\u003c\/th\u003e\n\u003ctd\u003eConfigurable as: Negative switching digital input Resistive sensor | OUTPUTS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput A (Fuel)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eOutput B (Start)\u003c\/th\u003e\n\u003ctd\u003e15 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003cth\u003eAuxiliary Outputs C, D, E, F, G \u0026amp; H\u003c\/th\u003e\n\u003ctd\u003e2 A DC at supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"DSE","offers":[{"title":"Default Title","offer_id":52597217689876,"sku":"1132","price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/files\/DSE6110MKIII-Auto-Start-Control-Module_72d16853-e42e-41af-8686-b02436652bab.jpg?v=1780704388"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/2935\/6564\/collections\/dse-control.png?v=1782434624","url":"https:\/\/www.macfarlanegenerators.com.au\/collections\/dse-deep-sea-electronics.oembed","provider":"Macfarlane Generators","version":"1.0","type":"link"}